Validation of warfarin enantiomer analysis method in plasma using high-performance liquid chromatography fluorescence detector


1 Department of Pharmaceutics and Pharmaceutical Technology, Universitas Padjadjaran, Jalan Raya Bandung-Sumedang, Jatinangor, Indonesia
2 Department of Biology Pharmacy, Faculty of Pharmacy, Universitas Padjadjaran, Jalan Raya Bandung-Sumedang, Jatinangor, Indonesia
3 Department of Cardiovascular, Faculty of Medicine, Universitas Padjadjaran, Jalan Raya Bandung-Sumedang, Jatinangor, Indonesia
4 Laboratory of Pharmaceutical-Medicinal Chemistry and Bioanalysis, Faculty of Pharmacy, Universitas Indonesia, Depok, Indonesia

Correspondence Address:
Dr. Taofik Rusdiana
Raya Bandung Sumedang Road KM.21, Hegarmanah, West Java, Bandung 45363
Indonesia
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/japtr.japtr_259_21

Rights and Permissions

Warfarin (WF) is an anticoagulant commonly used for thromboembolism-related diseases.This study aims to assess the pharmacokinetic profile of WF. The stereospecific interaction of S-and R-WF requires quantification of the enantiomer to determine the pharmacokinetic profile. The analysis method of the enantiomers in plasma is developed using an HPLC fluorescence detector with a Chiralcel OD-RH column (4.6 mm × 150 mm i.d., 5 m) and a Chiralcel OD-RH guard column (4.0 mm × 10 mm, 5 m). The separation is conducted using isocratic with acetonitrile mobile phase: Phosphate buffer, pH 2.00 (40:60 v/v), column temperature 40°C, flow rate 1 mL/min, injection volume 50 L. WF is measured at an excitation wavelength of 310 nm and emission of 350 nm. This method results in limit of detection (LOD) values of 18.6 ng/mL and limit of quantitation (LOQ) of 62.01 ng/mL for R-WF and LOD values of 18.61 ng/mL and LOQ of 62.04 ng/mL for S-WF. The results showed a linearity in concentration between 100 and 2500 ng/mL with r2 = 0.9969 and r2 = 0.9991 for R-and S-WF. The validation requirements of selectivity, accuracy, and precision for within and between run with a value of <15% for % relative standard deviation and % diff were achieved. This method can be used in the sample measurement of WF pharmacokinetic studies.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1108    
    Printed48    
    Emailed0    
    PDF Downloaded143    
    Comments [Add]    

Recommend this journal